Skip to main content

Power Cables

Single Core & Multicore Flexible Cable

Orient Single & Multicore Flexible Copper Cable are used in low voltage signals, electrical motors, electrical appliances, control panels, DC power transformers, electrical boards, battery cables etc.

These cables are highly flexible in construction & designed with high Di-electric strength

Orient Single & Multicore Flexible Copper Cable are having high degree of thermal stability, Oxygen & temperature index. These cables retard its spread in the unlikely event of fire felicitating rescue operation

Technical Specification

FRFRLSZHFR
Type of Insulation70°C/105°C HEAT RESISTANT PVCFlame Retardant Low Smoke (FRLS)Halogen Free (HFFR) From 1.0 to 4.0 Sq.mm
Typical ApplicationsWiring of panels for use in high ambient temperatureWiring in high density critical installations in public places and fire prone areasWiring in high density critical installations in public places and vicinity of electronic systems
Applicable StandardsIS-694, BS 6004, IEC 60227, DIN VDE-0281-3IEC 60332-1, BS 4066-1, IEC-60754-1, ASTMD-2843, ASTMD-2863IEC 60332-1&3, BS 4066-1&3, IEC 60754-1&2, ASTMD-2863, BS 7211, DIN VDE-0282-9

Single Core Insulated Copper Conductor (unsheathed) flexible cables, 1100 voltage grade for industrial application 

Nominal  Cross Sectional  Area of  ConductorNumber/ Nom. Dia. Of Cond. Strands*Thickness  of  Insulation
(Nom)
Approx. 

Overall  

Diameter

Max. Current Max. Current carrying capacityMax. Conductor Resistance per km at 20 °C
Sq.mm mm mm mm Amps Ohms
10 80/0.4 1.0 6.30 55 1.91
16 126/0.4 1.0 7.40 75 1.21
25 196/0.4 1.2 9.10 100 0.780
35 276/0.4 1.2 10.30 125 0.554
50 396/0.4 1.4 12.20 165 0.386
70 354/0.5 1.4 14.10 240 0.272
95 484/0.5 1.6 16.40 300 0.206
120 608/0.5 1.6 18.00 325 0.161
150 750/0.5 1.8 20.10 352 0.129
185 925/0.5 2.0 22.30 415 0.106
240 1210/0.5 2.2 25.20 500 0.0801
300 1520/0.5 2.4 28.50 585 0.0641

Note: Conductor as per Class 5 IS:8130 packing lengths as per IS 694 and in bigger packing on request higher sizes of nominal cross-sectional area of conductor area also on request.
*The Number and Diameter of conductor strands are for reference only conductor resistance as per 8130 is the governing criteria. Construction:-
Conductor : plain annealed copper conductor as per IS: 8130
Insulation : Primary – Natural Type A PVC
Colour : AS PER IS:694

Technical Specification

Type of InsulationType of SheathingApplicable StandardsTypical Applications
Standard PVCStandard PVC, HRPVCIS 694, BS 6500, IEC 60227, DIN VDE-0281Power Cords for appliance, temporary power supplies, 3 core flat cables are suitable for submersible pump applications.
Heat Resistant PVC up to 105°CStandard PVC, HRPVCIS 694, BS 6500, IEC 60227, DIN VDE-0281Hi-power appliances, ovens, temporary power supply in higher temperature areas.
Standard PVC of FRLSFRLS (Flame Retardant Low Smoke)IS 694, BS 6500, IEC 60227, DIN VDE-0281, IEC 60754-1, IEC 60332-1, BS-4066-1, ASTMD 2843, ASTMD-2863Power cords for application used in fire prone areas, flame proof equipments, machine tools used in critical locations and heat zones

Orient Multicore Round Insulated Copper Conductor and Sheathed Flexible cables, 1100Voltage grade

Nominal Cross sectional Area of Conductor Sq.mmNumber/ Nom.Dia
.Of Conduct Stands* mm
Thickness of Insulation (mm) mmNominal Thickness of Sheath Approx. Overall Diameter Current Rating AC AMPSMax. conductor Resistance per  KM at 20°C Ohms
Two core
mm
Three core
mm
Four core
mm
Two core
mm
Three core
mm
Four core
mm
0.5 16/0.20 0.6 0.9 0.9 0.9 6.2 6.6 7.2 39.0
0.75 24/0.20 0.6 0.9 0.9 0.9 6.5 6.9 7.6 26.0
1.0 32/0.20 0.6 0.9 0.9 0.9 6.9 7.3 8.2 11 19.5
1.5 30/0.25 0.6 0.9 0.9 1.0 7.6 8.2 9.3 14 13.3
2.5 50/0.25 0.7 1.0 1.0 1.0 9.0 9.6 10.5 19 7.98
4.0 56/0.30 0.8 1.0 1.0 1.0 10.3 10.9 12.3 26 4.95
6.0 84/0.30 0.8 1.1 1.2 1.2 13.0 13.80 15.47 34 3.30
10 78/0.40 1.0 1.3 1.4 1.4 16.5 17.69 19.5 44 1.91
16 124/0.40 1.0 1.4 1.4 1.4 19.4 20.6 23.0 61 1.21
25 196/0.40 1.2 1.4 1.5 1.6 23.8 25.6 28.5 69 0.780
35 274/0.40 1.2 1.6 1.6 1.7 27.2 29.3 32.7 88 0.554
50 394/0.40 1.4 2.0 2.0 2.0 32 34.6 38.6 102 0.386
70 378/0.5 1.4 2.2 2.2 2.2 36.8 39.6 44.3 140 0.272
95 478/0.5 1.6 2.4 2.4 2.4 41.8 47.0 50.2 165 0.206
120 607/0.50 1.6 2.5 2.5 2.5 46.2 51.0 55.7 190 0.161
150 756/0.50 1.8 – 2.6 2.6 – 54.8 62.1 215 0.129
185 935/0.50 2.0 – 2.8 2.8 – 61.2 68.5 250 0.106
240 1214/0.5 2.2 – 3.0 3.0 – 69.7 77.9 295 0.0801

NOTE: – Conductor as per Class 5 IS:8130 Supplied in 100 meter length with black outer sheath and in bigger packing on request. Any color on specific request can be supplied, in economical run higher size of nominal cross sectional area of conductor area are also available on request.
*The number of diameter of conductor strands are for reference only. Conductor resistance as per IS: 8130 is the governing criteria.

Technical Specification

Conductor: Nicely bunched high purity bright, electrolytic grade, plain annealed copper with superb flexibility according to harmonized grades HO5V-K, HO7V-K, BS 6360 class 5 available in various sizes. 

Insulation & Sheathing: Generally available with general purpose insulation and normal PVC sheathing, choice of insulation and sheathing is available on special order. 

Three Core Flat Flexible Industrial Cable for Submersible Pump Motors, 1100 Voltage Grade

Nominal Area of ConductorINSULATION Overall Dimensions (Max.)Max.
Conductor
Resistance
at 20°C (Max.)
Current
Carrying
Capacity
at 40°C
*Number/ Size of Wire for each CoreThickness (Nom.)Core Dia. (Nom.) 
Width WHeight H
sq. mm Mm mm Mm mm mm Ohm/Km Amps.
1.50 30/0.25 0.6 2.9 12.0 5.6 13.3 14
2.50 50/0.25 0.7 3.5 13.0 6.2 7.98 18
4.00 56/0.30 0.8 4.0 15.3 7.1 4.95 26
6.00 84/0.30 0.8 4.90 19.20 8.4 3.3 31
10.00 80/0.40 6.20 24.2 10.40 1.91 42
16.00 126/0.40 7.30 29 12.40 1.21 57
25.00 196/0.40 1.2 8.90 36.50 15.70 0.78 72
35.00 276/0.40 1.2 10.10 40.5 17.20 0.554 90

Note: All Conductor as per Class 5 IS:8130. Supplied in 500+ 5% meter packing on drums. Can also be supplied in 100 meter packing on request. *The number and diameter of conductor strands are for reference only. Conductor resistance as per IS: 8130 is the governing criteria.
The above data is indicative and may be revised without prior intimation.

Formulated with special PVC compound to work in challenging working condition & atmosphere
High on abrasion (Mechanical) withstand capacity.
Excellent Fire & Heat retardant characteristics.
Better reliability, energy efficiency & highest level of safety with high Oxygen Index.
Highly flexible in nature felicitate easy handling at site.

For business inquiry fill the form or call (+91) 98110-09935.